Understanding the Basics
Defining Creepage and Clearance
Term | Definition | Measurement Method | Primary Concern |
---|
Creepage | Shortest path between conductors along surface | Following surface contours | Surface contamination |
Clearance | Shortest distance through air | Direct line measurement | Air breakdown voltage |
Why They Matter
Critical Factors Affecting Safety
Factor | Impact on Design | Risk if Ignored |
---|
Voltage | Higher voltage requires larger distances | Electrical arcing |
Pollution | Affects surface conductivity | Current leakage |
Altitude | Affects air insulation properties | Premature breakdown |
Material | Influences tracking resistance | Surface degradation |
Standards and Regulations
Key PCB Design Standards
Standard | Scope | Application |
---|
IPC-2221 | Generic PCB Design | General electronics |
IEC 60950-1 | Safety of IT Equipment | Computer hardware |
UL 60950 | Safety Requirements | North American market |
EN 60335-1 | Household Appliances | Consumer products |
Pollution Degrees
Degree | Description | Environment Type | Example Applications |
---|
1 | No pollution | Hermetically sealed | Medical implants |
2 | Non-conductive pollution | Office/home | Consumer electronics |
3 | Conductive pollution | Industrial | Factory equipment |
4 | Persistent conductivity | Outdoor | Weather stations |
Calculating Required Distances
Basic Clearance Requirements
Working Voltage (V) | Clearance (mm) |
---|
0-50 | 0.13 |
51-100 | 0.25 |
101-300 | 0.7 |
301-600 | 1.7 |
601-1000 | 2.8 |
Creepage Distance Requirements
Working Voltage (V) | Pollution Degree 1 (mm) | Pollution Degree 2 (mm) | Pollution Degree 3 (mm) |
---|
0-50 | 0.2 | 0.5 | 1.2 |
51-100 | 0.3 | 0.7 | 1.4 |
101-300 | 0.8 | 1.5 | 2.5 |
301-600 | 2.0 | 3.0 | 4.0 |
601-1000 | 3.2 | 4.5 | 6.0 |
Altitude Correction Factors
Altitude (m) | Multiplication Factor |
---|
0-2000 | 1.00 |
2001-3000 | 1.14 |
3001-4000 | 1.29 |
4001-5000 | 1.48 |
5001-6000 | 1.70 |
Material Considerations
Comparative Tracking Index (CTI)
Material Group | CTI Range | Common Materials | Typical Applications |
---|
I | ≥600 | High-grade FR4 | Medical devices |
II | 400-599 | Standard FR4 | Consumer electronics |
IIIa | 175-399 | Basic laminates | Industrial equipment |
IIIb | 100-174 | Basic materials | Low-cost applications |
Material Selection Guide
Application | Recommended Material | Minimum CTI | Rationale |
---|
High voltage | Group I | ≥600 | Maximum safety margin |
Industrial | Group II | ≥400 | Good balance |
Consumer | Group IIIa | ≥175 | Cost-effective |
Low voltage | Group IIIb | ≥100 | Minimal requirements |
Design Implementation
PCB Layout Techniques
Technique | Purpose | Implementation |
---|
Slot placement | Increase creepage | Cut slots between conductors |
Guard rings | Prevent leakage | Surround high-voltage areas |
Component spacing | Maintain clearance | Space components based on voltage |
Layer separation | Improve isolation | Use separate layers for voltage levels |
Common Design Patterns
Pattern | Application | Advantages | Disadvantages |
---|
Gridded ground | High-frequency | Good isolation | Complex routing |
Star ground | Mixed signal | Reduced interference | More space needed |
Isolation barrier | Safety critical | High reliability | Increased cost |
Interleaved traces | EMI reduction | Better noise immunity | Harder to modify |
Testing and Validation
Test Methods
Test Type | Purpose | Equipment Needed | Standard |
---|
Hi-pot test | Voltage breakdown | Hi-pot tester | IEC 60950-1 |
Insulation resistance | Leakage current | Megohmmeter | IEC 60601-1 |
Environmental | Pollution effects | Climate chamber | IEC 60068-2 |
Thermal cycling | Stress testing | Thermal chamber | IEC 61189-5 |
Quality Assurance Checklist
Check Point | Verification Method | Frequency |
---|
Design rules | DRC software | Every design |
Clearance measurements | Physical inspection | Prototype stage |
Material certification | Documentation review | New material |
Environmental testing | Lab testing | New product |
Special Considerations
High Voltage Applications
Voltage Range | Special Requirements | Additional Measures |
---|
>1000V | Double clearance | Conformal coating |
>2000V | Triple clearance | Potting compound |
>5000V | Custom design rules | Special materials |
>10000V | Expert consultation | Full encapsulation |
Extreme Environments
Environment | Challenges | Solutions |
---|
High humidity | Moisture conductivity | Conformal coating |
Salt spray | Corrosion | Special coatings |
Chemical exposure | Material degradation | Protective barriers |
High altitude | Air insulation | Increased spacing |
Frequently Asked Questions
Q1: How do I determine the minimum creepage distance for my PCB?
A: To determine minimum creepage distance, you need to consider:
- Working voltage
- Pollution degree of the environment
- Material group (CTI value)
- Altitude of operation
Use the tables provided in this guide and multiply the base value by any applicable correction factors.
Q2: What's the difference between functional and basic insulation?
A: Functional insulation is the minimum insulation needed for proper operation of the equipment, while basic insulation provides fundamental protection against electric shock. Basic insulation typically requires larger creepage and clearance distances than functional insulation, often 1.5 to 2 times greater.
Q3: Do I need to consider creepage and clearance between traces on different layers?
A: Yes, creepage and clearance requirements apply to conductors on different layers. Through-board clearance must be considered, and the PCB material's properties become crucial. The distance should be measured through the shortest possible path, including through-holes or vias.
Q4: How does conformal coating affect creepage requirements?
A: Conformal coating can reduce creepage requirements as it protects against pollution and moisture. However, it doesn't affect clearance requirements. Type 1 coating can reduce creepage requirements by one pollution degree, while Type 2 coating can reduce them by two degrees.
Q5: What are the common mistakes in creepage and clearance design?
A: Common mistakes include:
- Not considering altitude correction factors
- Ignoring pollution degree requirements
- Forgetting about through-hole and via spacing
- Not accounting for component height in clearance calculations
- Overlooking temperature effects on material properties
No comments: